SuperFlow VS Pump getting error code 02
4 posts / 0 new
Last post
Posted

my 2 month old Super Flow Variable Speed pump is getting an error code 02 and doesn't run. Is there any way to reset this?

Please Sign In to post comments
Richard's picture
Tech, Pentair
There would not be a reset
Richard's picture
Tech, Pentair
Posted

There would not be a reset for this matter, the error code 02 is showing a voltage issue that will need to be corrected. In the manual shows this code being Absolute Phase current limit exceeded on page 16. It would be advised to have an electrician review this matter.

http://www.pentairpool.com/pdfs/SuperFloVS1.5OM.pdf

Please Sign In to post comments
After I read the post from
Posted

After I read the post from Richard (Pentair Tech) I was about to panic having to deal with the maker and retailer where I got my Pentair SuperFlow; but I read in another forum a solution to a similar issue and I decide to try it first. For what I tried I did not have to take the pump apart or call an electrician I just shot down all power to the pump at the breaker panel, released the water pressure at the filter, removed the pump strainer lid and with my hand/fingers I reached the impeller thru the strainer chamber and I was able break away some sand particles from the propeller and making sure I could feel the impeller free to turn on both directions. After putting everything back together I fired up the pump and away it went with no problem.

Please Sign In to post comments
I was back flushing and 20
Posted

I was back flushing and 20 sec into it the pump shut off with Error 0211. I did the steps in El Chavo's post and the pump started up normally. Thanks

Please Sign In to post comments